<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Miscellaneous Archives - Midian Electronics</title>
	<atom:link href="https://midians.com/categories/miscellaneous/feed/" rel="self" type="application/rss+xml" />
	<link>https://midians.com/categories/miscellaneous/</link>
	<description>We specialize in MIniature DIgital and ANalog devices</description>
	<lastBuildDate>Fri, 30 Apr 2021 22:31:43 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://midians.com/wp-content/uploads/2020/11/cropped-midian-logo-300w-32x32.png</url>
	<title>Miscellaneous Archives - Midian Electronics</title>
	<link>https://midians.com/categories/miscellaneous/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>STI-2</title>
		<link>https://midians.com/products/sti-2/</link>
		
		<dc:creator><![CDATA[Allen Shea]]></dc:creator>
		<pubDate>Tue, 01 Dec 2020 00:26:23 +0000</pubDate>
				<guid isPermaLink="false">http://midians.com/?post_type=products&#038;p=1103</guid>

					<description><![CDATA[<p>Midian&#8217;s STI series adds telephone interconnect capability to radio systems. The STI offers up to 100 users. COR operation for PTT click counter with single memory dial is available for non-keypad users. Others features of the STI include call limit timers, toll restricts, automatic disconnect on busy signal, and more. The STI-2 is similar to [&#8230;]</p>
<p>The post <a href="https://midians.com/products/sti-2/">STI-2</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>Midian&#8217;s STI series adds telephone interconnect capability to radio systems. The STI offers up to 100 users. COR operation for PTT click counter with single memory dial is available for non-keypad users. Others features of the STI include call limit timers, toll restricts, automatic disconnect on busy signal, and more.</em></p>
<p><em>The STI-2 is similar to Zetron&#8217;s M45B Z-Patch.</em></p>
<ul>
<li><em>* and ANI for multi-user validation</em></li>
<li><em>Capable of simplex, half-duplex, or full-duplex operation</em></li>
<li><em>FCC Part 68 &amp; Part 15 approved</em></li>
<li><em>Offers up to 100 speed dials</em></li>
<li><em>Simple * up and # down operation in single user mode</em></li>
<li><em>Programmable via a Midian Programming Adapter</em></li>
</ul>
<a  data-e-Disable-Page-Transition="true" class="download-link" title="" href="https://midians.com/download/1625/?tmstv=1761639070" rel="nofollow" id="download-link-1625" data-redirect="false" >
	STI Manual</a>

<p>The post <a href="https://midians.com/products/sti-2/">STI-2</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>STI-1</title>
		<link>https://midians.com/products/sti-1/</link>
		
		<dc:creator><![CDATA[Allen Shea]]></dc:creator>
		<pubDate>Tue, 01 Dec 2020 00:17:51 +0000</pubDate>
				<guid isPermaLink="false">http://midians.com/?post_type=products&#038;p=1101</guid>

					<description><![CDATA[<p>Midian&#8217;s STI series adds telephone interconnect capability to radio systems. The STI offers up to 100 users. COR operation for PTT click counter with single memory dial is available for non-keypad users. Others features of the STI include call limit timers, toll restricts, automatic disconnect on busy signal, and more. The STI-1 is similar to [&#8230;]</p>
<p>The post <a href="https://midians.com/products/sti-1/">STI-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>Midian&#8217;s STI series adds telephone interconnect capability to radio systems. The STI offers up to 100 users. COR operation for PTT click counter with single memory dial is available for non-keypad users. Others features of the STI include call limit timers, toll restricts, automatic disconnect on busy signal, and more.</em></p>
<p><em>The STI-1 is similar to Zetron&#8217;s MS30 Worldpatch (also called Model 30 World Patch).</em></p>
<ul>
<li><em>* and ANI for multi-user validation</em></li>
<li><em>Capable of simplex, half-duplex, or full-duplex operation</em></li>
<li><em>FCC Part 68 &amp; Part 15 approved</em></li>
<li><em>Offers up to 100 speed dials</em></li>
<li><em>Simple * up and # down operation in single user mode</em></li>
<li><em>Programmable via a Midian Programming Adapter</em></li>
</ul>
<a  data-e-Disable-Page-Transition="true" class="download-link" title="" href="https://midians.com/download/1625/?tmstv=1761639070" rel="nofollow" id="download-link-1625" data-redirect="false" >
	STI Manual</a>

<p>The post <a href="https://midians.com/products/sti-1/">STI-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VAE-80</title>
		<link>https://midians.com/products/vae-80/</link>
		
		<dc:creator><![CDATA[Allen Shea]]></dc:creator>
		<pubDate>Mon, 30 Nov 2020 23:52:51 +0000</pubDate>
				<guid isPermaLink="false">http://midians.com/?post_type=products&#038;p=1096</guid>

					<description><![CDATA[<p>The VAE-80 is a voice alarm encoder capable of playing back 8 different 20 second user pre-recorded messages over a radio channel. Each of these 8 messages is controlled by 8 individual logic low inputs (relay contacts) from an alarm panel. Optional dedicated phone line port for activating the pre-recorded messages remotely using a telephone. [&#8230;]</p>
<p>The post <a href="https://midians.com/products/vae-80/">VAE-80</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>The VAE-80 is a voice alarm encoder capable of playing back 8 different 20 second user pre-recorded messages over a radio channel. Each of these 8 messages is controlled by 8 individual logic low inputs (relay contacts) from an alarm panel. Optional dedicated phone line port for activating the pre-recorded messages remotely using a telephone.</em></p>
<p><em>The VAE-80 is similar to Zetron&#8217;s M1517 Alarm Reporter.</em></p>
<p><em>Features:</em></p>
<ul>
<li><em>Stores 8 pre-recorded 20 second messages for instant playback when triggered with a logic low on any of its 8 inputs.</em></li>
<li><em>Programmable repeat of recorded messages to ensure they are heard.</em></li>
<li><em>All programming and pre-recorded messages can be changed via the Midian programming adapter or the included administrative microphone.</em></li>
</ul>
<a  data-e-Disable-Page-Transition="true" class="download-link" title="" href="https://midians.com/download/1731/?tmstv=1761639070" rel="nofollow" id="download-link-1731" data-redirect="false" >
	VAE-80 Manual</a>

<p>The post <a href="https://midians.com/products/vae-80/">VAE-80</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>PARTI-1</title>
		<link>https://midians.com/products/parti-1/</link>
		
		<dc:creator><![CDATA[Allen Shea]]></dc:creator>
		<pubDate>Mon, 30 Nov 2020 23:43:24 +0000</pubDate>
				<guid isPermaLink="false">http://midians.com/?post_type=products&#038;p=1094</guid>

					<description><![CDATA[<p>When seconds count in an emergency Midian&#8217;s PARTI-1 enables remote access to an existing Public Address System via two-way radio with an option for cellular, VoIP and land-line telephone. Once connected the user can transmit a live, &#8220;buffered&#8221; or pre-recorded message with alert tone and message repeat over the PA System. Campuses: Schools, Universities, Business: Active [&#8230;]</p>
<p>The post <a href="https://midians.com/products/parti-1/">PARTI-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>When seconds count in an emergency Midian&#8217;s PARTI-1 enables remote access to an existing Public Address System via two-way radio with an option for cellular, VoIP and land-line telephone. Once connected the user can transmit a live, &#8220;buffered&#8221; or pre-recorded message with alert tone and message repeat over the PA System.</em></p>
<p><em><b>Campuses: Schools, Universities, Business:</b> Active Shooter Response, lockdown, pre-recorded security level notifications, intruder alerts, fire, disaster alerts, school bus mass evacuation &amp; hijackings</em></p>
<p><em><b>Airports:</b> TSA/Police live, &#8220;buffered&#8221; or pre-recorded announcements with alert tone and message repeat, vehicular traffic control</em></p>
<p><em><b>Industrial Plants &amp; Mining:</b> Accidents, toxic spills, live in-plant paging, inclement weather notification</em></p>
<p><em><b>Hospitals:</b> Ambulance arrival notification, Active Shooter Response, intruder alerts, fire, disaster alerts</em></p>
<p><em><b>Government &amp; Private Buildings:</b> Unauthorized persons, fire, disaster alerts, live in-plant paging</em></p>
<p><em><b>Shopping Malls, Amusement Parks, Parking Lots:</b> Pre-recorded advertising message with repeat, live in-plant paging</em></p>
<p><em>The PARTI-1 is similar to:</em><br />
<em>• Zetron&#8217;s M1517 Alarm Reporter</em><br />
<em>• GAI-Tronics&#8217; ACC2500 Audio Control Center</em><br />
<em>• Motorola&#8217;s SchoolSAFE</em><br />
<em>• Ritron&#8217;s LoudMouth wireless PA system</em></p>
<p><em>Features:</em></p>
<ul>
<li><em>Can store 8 pre-recorded messages for instant playback by using the Touch Tone® keypad on the user&#8217;s radio</em></li>
<li><em>To avoid feedback over the PA System the user may record a &#8220;buffered&#8221; message which will be played immediately</em></li>
<li><em>Live voice messages may be transmitted in real time over PA System</em></li>
<li><em>Radio and telephone audio can interface directly to the XLR microphone connector or accessory connector on the PA</em></li>
<li><em>Relay output to activate all call/emergency on PA System</em></li>
</ul>
<a  data-e-Disable-Page-Transition="true" class="download-link" title="" href="https://midians.com/download/1600/?tmstv=1761639070" rel="nofollow" id="download-link-1600" data-redirect="false" >
	PARTI-1 User Manual</a>

<p>The post <a href="https://midians.com/products/parti-1/">PARTI-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>AE-1</title>
		<link>https://midians.com/products/ae-1/</link>
		
		<dc:creator><![CDATA[Allen Shea]]></dc:creator>
		<pubDate>Mon, 30 Nov 2020 23:12:00 +0000</pubDate>
				<guid isPermaLink="false">http://midians.com/?post_type=products&#038;p=1092</guid>

					<description><![CDATA[<p>The AE-1 can monitor up to 8 inputs at remote locations with telemetry radio using two-tone, five-tone, or DTMF. Each input can have 2 status messages assigned to it such as open/closed, high/low, on/off, etc. The AE-1 can report a single alarm/condition to a two-tone or five-tone pager. It can also report multiple alarm conditions [&#8230;]</p>
<p>The post <a href="https://midians.com/products/ae-1/">AE-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>The AE-1 can monitor up to 8 inputs at remote locations with telemetry radio using two-tone, five-tone, or DTMF. Each input can have 2 status messages assigned to it such as open/closed, high/low, on/off, etc. The AE-1 can report a single alarm/condition to a two-tone or five-tone pager. It can also report multiple alarm conditions to Midian&#8217;s CAD-100 and CAD-200. When using the CAD-100/200, information can be logged to a computer or printer.</em></p>
<p><em>The AE-1 can be used to monitor and control pumps, generators, irrigation systems, lighting systems, fluid levels, and more.</em></p>
<ul>
<li><em>Each input can be programmed with 2 statuses</em></li>
<li><em>Monitor up to 8 inputs</em></li>
<li><em>Report alarm conditions to Midian&#8217;s CAD-100/200</em></li>
</ul>
<a  data-e-Disable-Page-Transition="true" class="download-link" title="" href="https://midians.com/download/1515/?tmstv=1761639070" rel="nofollow" id="download-link-1515" data-redirect="false" >
	AE-1 User Manual</a>

<p>The post <a href="https://midians.com/products/ae-1/">AE-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ID-1</title>
		<link>https://midians.com/products/id-1/</link>
		
		<dc:creator><![CDATA[Allen Shea]]></dc:creator>
		<pubDate>Sun, 29 Nov 2020 18:09:33 +0000</pubDate>
				<guid isPermaLink="false">http://midians.com/?post_type=products&#038;p=871</guid>

					<description><![CDATA[<p>The ID-1 offers cost-effective and easy to use automatic Morse Code Identification. The ID-1 has 2 Station ID&#8217;s with programmable tone frequency, duty cycle, and transmission speed. Other features of the ID-1 include key-up delay, hang time, and time-out timer. Programmable via Midian programming adapter or using an optional keypad Programmable hang time Programmable message [&#8230;]</p>
<p>The post <a href="https://midians.com/products/id-1/">ID-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>The ID-1 offers cost-effective and easy to use automatic Morse Code Identification. The ID-1 has 2 Station ID&#8217;s with programmable tone frequency, duty cycle, and transmission speed. Other features of the ID-1 include key-up delay, hang time, and time-out timer.</em></p>
<ul>
<li><em>Programmable via Midian programming adapter or using an optional keypad</em></li>
<li><em>Programmable hang time</em></li>
<li><em>Programmable message transmit speed</em></li>
<li><em>Selectable go-ahead beep on loss of PTT</em></li>
<li><em>Two messages or station ID&#8217;s</em></li>
<li><em>Wait period after loss of carrier (aka COR) or CTCSS</em></li>
</ul>
<a  data-e-Disable-Page-Transition="true" class="download-link" title="" href="https://midians.com/download/1567/?tmstv=1761639070" rel="nofollow" id="download-link-1567" data-redirect="false" >
	ID-1 User Manual</a>

<p>The post <a href="https://midians.com/products/id-1/">ID-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>VTE-1</title>
		<link>https://midians.com/products/vte-1/</link>
		
		<dc:creator><![CDATA[Allen Shea]]></dc:creator>
		<pubDate>Sat, 28 Nov 2020 04:28:58 +0000</pubDate>
				<guid isPermaLink="false">http://midians.com/?post_type=products&#038;p=638</guid>

					<description><![CDATA[<p>The voting tone encoder (also known as a pilot tone generator or status tone generator) with a 600-ohm line driver, pairs with a radio receiver to create an analog satellite voting receiver or auxiliary receiver. Satellite voting receivers are spread out over a geographic area to provide greater radio coverage and are connected via a [&#8230;]</p>
<p>The post <a href="https://midians.com/products/vte-1/">VTE-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><em>The voting tone encoder (also known as a pilot tone generator or status tone generator) with a 600-ohm line driver, pairs with a radio receiver to create an analog satellite voting receiver or auxiliary receiver. Satellite voting receivers are spread out over a geographic area to provide greater radio coverage and are connected via a dedicated line, telemetry link or microwave to a voting comparator. The voting comparator looks at the signal to noise ratio from multiple voting receivers and passes the best quality signal to the dispatcher/repeater.</em></p>
<p><em>Midian&#8217;s VTE-1 can be used with voting comparators that look for a 1950 Hz, 2175 Hz, 1600 Hz or 2700 Hz voting tone such as Motorola&#8217;s SpectraTAC, JPS Communications&#8217; SNV-12, GE Mastr II, etc.</em></p>
<ul>
<li><em>2175, 1950, 1600 or 2700 Hz voting tones set by jumpers.  No programming software required.</em></li>
<li><em>Built-in line driver (600 Ohm)</em></li>
<li><em>Custom tones available</em></li>
</ul>
<a  data-e-Disable-Page-Transition="true" class="download-link" title="" href="https://midians.com/download/1771/?tmstv=1761639070" rel="nofollow" id="download-link-1771" data-redirect="false" >
	VTE-1 Manual</a>

<p>The post <a href="https://midians.com/products/vte-1/">VTE-1</a> appeared first on <a href="https://midians.com">Midian Electronics</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
